ELECTRICAL:
●VOLTAGE RATING: The cable should be rated for DC voltage up to 300V for a duration of 10 milliseconds, ensuring that it can safely handle this level of electrical potential without damage.
●CONDUCTANCE RESISTANCE: The maximum conductance resistance of the cable should not exceed 3.0 ohms, which is important for efficient transmission of electrical signals and minimizing power loss.
●INSULATION RESISTANCE: The insulation of the cable should have a minimum resistance of 5.0 megaohms to prevent leakage of current and ensure proper isolation between conductors.
●100% ELECTRICAL TEST: The cable must undergo a comprehensive electrical test to verify its performance and safety under operational conditions.
● QUALITY CHECKS: The cable should be free from any open circuits, short circuits, miswiring, or intermittent failures to guarantee reliable operation in electrical systems.
MATERIAL:
●REFER TO TABLE: Specific materials used in the cable construction should be referenced in a detailed table, specifying the composition and properties of each component.
ROHS COMPLIANT:
●All components utilized in the cable assembly must comply with the RoHS regulations, which restrict the use of hazardous substances in electronic products to promote environmental protection and human health.